109
SV200 DC Hardware Manual
920-0126A
4/14/2017
7.5.1.3 Homing settings
Homing Method:
There are 12 types of homing available.
Search Homing:
Sets the velocity, acceleration and deceleration while searching for the homing switch.
Search Index:
This feature sets the velocity, acceleration and deceleration while searching for the motor encoder index signal after
the homing switch has been reached.
Homing Offset:
After the homing process has finished, this sets the offset value from the home position.
7.5.1.4 Print
Click Print to print out the configuration table,
7.5.1.5 Position Definition
Positon Definition shows the detailed configuration for each position point, including velocity, acceleration, deceleration, and position.
This table, also shows the input condition of X7 - X12 to select each position.
M0(X7) - M5(X12) status:
‘0’ means the input is closed; ‘1’ means the input is open.
After the homing process, the motor will move to the corresponding position selected by inputs M0(X7) - M5(X12), and triggered by
X4 (position trigger) when it changes from ‘open’ to ‘closed’.
• Click OK to finish linear mode settings
• Click Download to Drive to send it to the drive
• Close the software, turn off the power, then restart both the drive and the software to run Position Table mode.