119
SV200 DC Hardware Manual
920-0126A
4/14/2017
P-06 (KK)
Inertia Feedforward Constant
Data Range
Default
Unit
LED Display
0~32767
500
------
500
The servo control inertia feed forward gain. Gain value is relative: “0” meaning no gain, “32767” meaning full gain. KK improves
acceleration control by compensating for the load inertia.
Without KK parameter, Inertia Feedforward Constant.
Red Line (Dash) : Actual velocity
Green Line (Filled) : Position error
With KK parameter, Inertia Feedforward Constant.
Red Line (Dash) : Actual velocity
Green Line (Filled) : Position error
P-07 (KJ)
Jerk Filter Frequency
Data Range
Default
Unit
LED Display
0~5000
5000
------
5000
This parameter sets the jerk filter frequency in Hz . The lower the frequency value the more pronounced the S-curve profile will be.
Setting the value to 0 will disable the filter.
S-curve acceleration/deceleration ramps are beneficial in positioning systems where instantaneous changes in speed may cause the
load to jerk excessively. One example is when the load is connected to the motion actuator via a long movement arm. If the arm is
not sufficiently rigid, changes in speed at the actuator can result in undesirable oscillations and increased settling time at the load.
Smoothed transitions in speed changes can alleviate this unwanted motion and reduce settling time.
Command
Time
Command
Time
Without Jerk Smoothing Filter
With Jerk Smoothing Filter