![AND Explosion Protected Weighing Indicator AD-4403-FP ST Series Instruction Manual Download Page 95](http://html1.mh-extra.com/html/and/explosion-protected-weighing-indicator-ad-4403-fp-st-series/explosion-protected-weighing-indicator-ad-4403-fp-st-series_instruction-manual_2941315095.webp)
C-8
outF—Control Output Functions
Function #
Function name
Range
outF-01 - 06
Control output; Capability of pins #10, 11,
14, 15, 18, and 19 of the control signal
terminals inside the case.
outF-01: 1
outF-02: 2
outF-03: 3
outF-04: 4
outF-05: 5
outF-06: 6
0
No capability
1
Zero band
2
Under limit
(Hi-Hi)
3
Over limit
(Hi)
4
Full-flow (Go)
5
Medium-flow (Lo)
6
Dribble-flow (Lo-Lo)
*(Type B)
7
Discharge gate open
8
Batch finish
9
Acceptable weight
10
Full
11
Nozzle down
12
Stable
13
Online
14
Weighing sequence running
15
Weighing sequence error
16
Input acknowledge
17
Zero range error
18
Weighing capacity overflow
19
Low battery
20
Accumulated weight/count overflow
21
Weighing unit converting
Summary of Contents for Explosion Protected Weighing Indicator AD-4403-FP ST Series
Page 22: ...2 7 Blank page...
Page 36: ...6 3 Blank page...
Page 38: ...6 5...
Page 40: ...6 7...
Page 53: ...6 20 Blank page...
Page 73: ...8 18 Blank page...
Page 83: ...Dimensions OP 20 Stand A 5...
Page 85: ...A 7 Blank page...
Page 87: ...B 2 Blank page...
Page 105: ...Fig Apx D 02 Gravity map WMF D 2...
Page 107: ...Form F Factory setting rSF 02 5 Command mode Address None rSF 09 0 Address 1 rSF 09 1 E 2...