6-6
6-4
CALF-14=“2” Weighing Mode
(Loss-In-weigh in customer programmed control mode)
Output signal
Output condition
Zero band
Gross weight
≤
Zero band
Full
Full
≤
Gross weight
Full-flow Final
-
Optional preliminary
≤
- Net weight
Medium-flow Final
-
Preliminary
≤
- Net weight
Dribble-flow Final
-
Free fall
≤
- Net weight
Over limit
Final +
Over limit
<
Net weight
Under limit
- Net weight
<
Final -
Under limit
•
When an output condition is established, a relevant output terminal is turned on (power continuity with output COM).
•
An output terminal number can be selected with OUTF-01 through OUTF-08. See {Appendix C: Function List}
•
A set point signal output is turned off unconditionally when the operation mode is other than the normal mode.
Weighing process
*
Programming with a PLC (Programmable Logic Controller) is required for this weighing mode.
*
Difference from the normal batching is that the loss-in weigh has “full” output and the comparison
is done with a negative net weight.
Sequence #
Process
1
•
With the weighing hopper 2 being empty, the gross weight is within the zero
range.
2
•
Gate G1 (Filling gate) opens.
•
The weight on the display is incremented, and reaches the “Full” weight.
•
The “Full” output is turned ON.
•
Gate G1 closes. (Weighing hopper 2 has been filled.)
3
•
The “Tare” signal is input.
•
The display shows “0”.
4
•
Gates G2 (full-flow), G3 (medium-flow), and G4 (dribble-flow) open.
•
The display shows the weight of “Final – Optional Preliminary”.
•
The “Optional Preliminary” output is turned ON.
•
Gate G2 closes.
5
•
The display shows the weight of “-(Final – Preliminary)”.
•
The “Preliminary” output is turned ON.
•
Gate G3 closes.
6
•
The display shows the weight of “-(Final – Free fall)”.
•
The “Final” output is turned ON.
•
Gate G4 closes.
•
Weighing completes at a stable display.
*
The indicator shows the final weight(negative), indicating that hopper 3 has
been filled to that weight. The use of over limit/under limit setting can check
whether the weight is within limits.
7
•
When the volume of ingredient left in the weighing Hopper 2 becomes less
than the Zero band.
•
The “Zero band” output signal is turned on.
*
Note: SQF-21/ SQF-22 setting enables to add automatically Final weight to Zero band or Full.
Therefore there is always enough ingredient left in the hopper for a measurement.
Summary of Contents for Explosion Protected Weighing Indicator AD-4403-FP ST Series
Page 22: ...2 7 Blank page...
Page 36: ...6 3 Blank page...
Page 38: ...6 5...
Page 40: ...6 7...
Page 53: ...6 20 Blank page...
Page 73: ...8 18 Blank page...
Page 83: ...Dimensions OP 20 Stand A 5...
Page 85: ...A 7 Blank page...
Page 87: ...B 2 Blank page...
Page 105: ...Fig Apx D 02 Gravity map WMF D 2...
Page 107: ...Form F Factory setting rSF 02 5 Command mode Address None rSF 09 0 Address 1 rSF 09 1 E 2...