![AND Explosion Protected Weighing Indicator AD-4403-FP ST Series Instruction Manual Download Page 35](http://html1.mh-extra.com/html/and/explosion-protected-weighing-indicator-ad-4403-fp-st-series/explosion-protected-weighing-indicator-ad-4403-fp-st-series_instruction-manual_2941315035.webp)
6-2
6-2 Weighing
Modes
The indicator-FP has 10 weighing modes, which vary from the weighing method (normal batching or
loss-in weigh) and with/without a PLC (Programmable Logic Controller).
Choose the mode suitable for your weighing at CALF-14. (See {Appendix C: Function List})
Utility
PLC.
Type of weighing
Weighing mode
Section
Normal batching 3)
Normal batching
(Customer Programmed Control Mode)
6-3
In use
1)
Loss-in-weigh 4)
Loss-in-weigh
(Customer Programmed Control Mode)
6-4
Without supplementary flow
Normal batching
(Built-in automatic program mode)
6-5
Normal
batching
3)
With supplementary flow
Normal batching
(Built-in automatic program mode)
6-6
Loss-in-weigh 4)
Loss-in-weigh
(Built-in automatic program mode)
6-7
Hopper
scale
Not in
use
2)
Nozzle Controlled Weighing Mode 5)
Nozzle Controlled Weighing Mode
(Built-in automatic program mode)
6-8
3-stage check weighing
with Over/Under limit
weight-deviation
Check weighing 1
6-9
5-stage check weighing
Check weighing 2
6-10
3-stage check weighing
with Over/Under limit
weight-deviation
Check weighing 3
6-11
Platform
Scale,
Check
weighing
scale
In use
1)
Check
weighing
6)
5-stage check weighing
Check weighing 4
6-12
1) PLC in use:
A programmed PLC is required besides the indicator to control the weighing process.
2) PLC not in use:
The built-in program of the indicator controls the weighing process.
3) Normal batching:
Weighs ingredient, controlling the increase in weight by comparing the measured weight with the
set point weight.
4) Loss-in-weigh:
Weighs ingredient, controlling the loss in weight by comparing the measured weight with the set
point weight.
5) Nozzle Controlled Weighing Mode:
Normal batching mode with tare function and nozzle control function.
6) Check weighing:
Weighs ingredient by comparing the measured weight with the target weight, and judges the
result in three ranks, Hi, Go, Lo.
Summary of Contents for Explosion Protected Weighing Indicator AD-4403-FP ST Series
Page 22: ...2 7 Blank page...
Page 36: ...6 3 Blank page...
Page 38: ...6 5...
Page 40: ...6 7...
Page 53: ...6 20 Blank page...
Page 73: ...8 18 Blank page...
Page 83: ...Dimensions OP 20 Stand A 5...
Page 85: ...A 7 Blank page...
Page 87: ...B 2 Blank page...
Page 105: ...Fig Apx D 02 Gravity map WMF D 2...
Page 107: ...Form F Factory setting rSF 02 5 Command mode Address None rSF 09 0 Address 1 rSF 09 1 E 2...