![AND Explosion Protected Weighing Indicator AD-4403-FP ST Series Instruction Manual Download Page 66](http://html1.mh-extra.com/html/and/explosion-protected-weighing-indicator-ad-4403-fp-st-series/explosion-protected-weighing-indicator-ad-4403-fp-st-series_instruction-manual_2941315066.webp)
8-11
Format Type
Format Name
Form E
Set Point Setting Format
See {Appendix E: Data output examples}
Code
:6
1
Final(Go):+1
000
Free fall(N/A):-25
Preliminary
(Hi-Hi):+1
50
Option
al preli
m
inar
y
Lo-
Lo
:+40
0
Over limit
Hi
+12
Under limit(L
o
+5
Zero ban
d
+1
0
Full (N/A):+16000
P
res
et T
a
re
+1763
T
e
rminator
•
Type B model for the Check
weighing
•
This format is available only in
command mode.
•
Data length: 76 bytes ( 60 bytes)
•
Set “SSXX” command ignoring decimal
point. Decimal point will cause an error.
•
“RSXX” command ignores decimal
point.
61
+0001
000
-0000
025
+0000
150
+00
004
00
+0000
012
+0000
005
+00
000
10
+0016
000
+00
017
63
CR
LF
Form F
Function Data Read-Out/Write-in Format
•
This format is available only in the command mode.
•
Function Data is read out from Basic functions to Calibration functions.
•
“EOF (1Ah)” is output after recalling the last data.
Read-out
Write-in
Function #
Setting Data
with polarity and
decimal point
Term.
Function
#
Setting Data
with polarity and
decimal point
Term.
FNC01 , +12345678
C
R
L
F
E
O
F
FNC01
,
+12345678
C
R
L
F
Form G
Code number Read-Out/Write-in Format
Code
Code #
61
Sep
a
rator
Final
Final Setting
value
Sep
a
rator
Free Fall
Free Fall Setting
value
…
Se
ttin
g
value
To
ta
l nu
mb
e
r
o
ver
flow
1s or
0
s
T
e
rminator
COD
E
61
FINAL
+00
010
0
F _F
ALL
-000
002
5
NO OF
0000
000
00
CR
LF
EOF
•
This format is available only in command
mode.
•
Read-out and Write-in are performed in the
following order;
Final (FINAL), Free Fall (F FALL), Prelim
(PRELIM), Optional preliminary (OP
PRELIM), Over Limit (OVER), Under Limit
(UNDER), Full (FULL), Preset Tare (TARE),
Accumulated Weight (TTL WT),
Accumulated Number (TTL NO),
Accumulated Weight Overflow (TTL OF).
•
“EOF (1Ah)” is output after recalling the last
data.
•
Write-in is performed code by code.
•
Overflow/ Underflow flag;
0: Not Overflow / Underflow
1: Overflow / Underflow
Summary of Contents for Explosion Protected Weighing Indicator AD-4403-FP ST Series
Page 22: ...2 7 Blank page...
Page 36: ...6 3 Blank page...
Page 38: ...6 5...
Page 40: ...6 7...
Page 53: ...6 20 Blank page...
Page 73: ...8 18 Blank page...
Page 83: ...Dimensions OP 20 Stand A 5...
Page 85: ...A 7 Blank page...
Page 87: ...B 2 Blank page...
Page 105: ...Fig Apx D 02 Gravity map WMF D 2...
Page 107: ...Form F Factory setting rSF 02 5 Command mode Address None rSF 09 0 Address 1 rSF 09 1 E 2...