Epica DGX 144 SC Fiber Boards
49
Epica DGX 144 Instruction Manual
4.
Insert the fiber cable connector into the input and output SC fiber receptacles (FIG. 25).
5.
Tie the SC fiber cable to the cable management bar far enough below the connector to allow for the
manufacturer’s recommended bend radius. The bend radius for AMX SC terminated fiber cables is
2 inches (5 cm).
6.
Repeat the previous steps for the remaining fiber cables.
Important:
The RS-232 connection on the modules requires management of the RS-232 data line in
relation to switching operations. In an upstream matrix switching scenario, we recommend that
RS-232 control commands (via the DGX RS-232 data connection) are not sent immediately prior or
subsequent to a matrix switching command. It is possible for the RS-232 data to be corrupted as the
video (or audio) signal is removed and then restored by the matrix switcher.
FIG. 25
Fasten cables onto input and output connectors (shown with cable management bar)
Tie cable to cable management bar
far enough below connector to allow
for manufacturer’s recommended
bend radius
Summary of Contents for Epica DGX 144
Page 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Page 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Page 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Page 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Page 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Page 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Page 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...