Appendix C – APDiagnostics
85
Epica DGX 144 Instruction Manual
Information Pane Plot Views
A Plot Views window displays a graph of data points for its associated components. The graph has a
legend at the right and is time-stamped in intervals across the bottom. The amount of historical data
points presented in the graph can be determined by changing the settings in the Application Preferences
dialog box (see page 88).
The legend in a Plot View is selectable; doing so will filter the view so that only the selected items are
displayed. Furthermore, if only a single item is selected, its Warning and Error setpoint values will also
be displayed in the window for reference.
Tip:
For a hard copy of a graph, save as a .png file, then print the .png.
For information on changing the viewing of the graph, see the APDiagnostics Help file.
To display System information:
1.
In the Categories pane, select the System tab.
2.
Click the desired System button to display its corresponding details in the Information pane:
To access graph options:
Right click on the graph and select a shortcut menu item.
Properties
– opens a Chart Properties dialog box with
three tabs: Title, Plot, and Other.
Save as
– opens a standard Save dialog box.
– opens a standard Page Setup dialog box.
Zoom In
– provides options to zoom in on Both Axes,
Domain Axis, or Range Axis.
Zoom Out
– provides options to zoom out on Both Axes,
Domain Axis, or Range Axis.
Auto Range
– provides options for auto display of Both
Axes, Domain Axis, or Range Axis.
Enclosure Info
– Enclosure Info, XNNet ID, Firmware Version Driver,
Version Build Date.
VM Configurations
– A table with the VM Name, VM Number, Inputs,
and Outputs.
Hardware Boards
– A table with board numbers for Inputs, Outputs, and
Center boards.
Power Supply Info
– Model number, Serial number, Revision, and Service
Hours for each power supply. (If a power supply is listed as “not reporting,”
either the power supply is not physically present or it is not being reported
by the enclosure.)
Signal Sense
(input) – A table indicates whether a signal is present on each
of the input channel connections on the switcher. The signal may or may not
be routed, but the source device must be connected and powered on for the
table to indicate that the signal is present.
Note:
The Signal Sense table does not show crosspoint status
.
Summary of Contents for Epica DGX 144
Page 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Page 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Page 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Page 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Page 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Page 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Page 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...