Installation and Setup
28
Epica DGX 144 Instruction Manual
Linking More Than Two Enclosures
Linking an Epica DGX 144 enclosure to multiple other types of enclosures (other than linking in a daisy
chain off an enclosure with a 10Base-2 / BNC connector) requires a Multi-Port Switch and RJ-45
straight-through patch cables. Depending on the other types of enclosures, a Media converter(s) and
RG-58 coax cable(s) may also be required. FIG. 12 below shows an Epica DGX 144 enclosure linked to
an Optima and to a Modula using a 5-Port Switch and a Media Converter.
Important:
If the system has an RJ-45 connector labeled TCP/IP, do not use it for linking
enclosures. Do not use an RJ-45 enclosure linking connector for a TCP/IP connection.
Cable Length Requirements
Note:
If you have questions regarding cabling or network related issues in conjunction with using a
Multi-Port Switch (or hub) for linking enclosures, contact your network administrator.
When attaching multiple enclosures to a Multi-Port Switch, one or more can be connected directly to
the Multi-Port Switch (see steps below) and/or one or more can use a Media Converter to connect to
the Multi-Port Switch (see steps on page 29). In a system with multiple 10Base-2 enclosures, only one
needs to be attached to the Multi-Port Switch with a Media Converter. The rest can be daisy-chained.
To link an Epica DGX 144 enclosure to a Multi-Port Switch:
1.
Insert one end of the RJ-45 straight-through patch cable into the Enc Link (RJ-45) Ethernet port on
the Epica DGX 144 enclosure.
2.
Insert the other end of the RJ-45 straight-through patch cable into the Multi-Port Switch.
3.
Repeat Steps 1 and 2 for enclosures with 10Base-T ports.* For 10Base-2 ports, go to page 29.
* Applies when linking an Optima, Optima SD, Precis SD, or Epica DGX 16/32 to a Multi-Port Switch
.
Important:
Attach 50-ohm termination connectors to the open ends of the T-connectors on the
Media Converter and on the last enclosure on the cable run.
Network Segment
Cable Type
Maximum Distance
Epica DGX 144 to Multi-Port Switch
RJ-45 straight-through patch
100 ft. (30.5 m)
Multi-Port Switch directly to another type enclosure RJ-45 straight-through patch
100 ft. (30.5 m)
Multi-Port Switch to Media Converter
RJ-45 straight-through patch
100 ft. (30.5 m)
Media Converter to last enclosure in daisy chain
RG-58 coax
10 ft. (3.05 m) total
FIG. 12
Epica DGX 144 enclosure linked to an Optima and a Modula
The total length of all cables between the
Media Converter and the last enclosure in a
daisy chain cannot exceed 10 ft. (3.05 m).
Straight-through patch cable - max. 100 ft. (30.5 m) each cable
RG-58 coax cable
Max. 10 ft. (3.05 m)
Media Converter
5-Port Switch
50-ohm termination connectors
Link
Link Modula
(See steps above)
(See steps
Link Optima
(See steps above)
on next page)
Epica DGX 144
Summary of Contents for Epica DGX 144
Page 10: ...Notices 6 Epica DGX 144 Instruction Manual ...
Page 20: ...Overview and General Specifications 16 Epica DGX 144 Instruction Manual ...
Page 48: ...Installation and Setup 44 Epica DGX 144 Instruction Manual ...
Page 54: ...Epica DGX 144 SC Fiber Boards 50 Epica DGX 144 Instruction Manual ...
Page 72: ...Appendix A EDID Programmer 68 Epica DGX 144 Instruction Manual ...
Page 82: ...Appendix B Managing Configuration Files 78 Epica DGX 144 Instruction Manual ...
Page 106: ...Appendix E Board Replacement 102 Epica DGX 114 Instruction Manual ...