A3.4 Installing the Mounting Flanges
The Model 4500 MkIII is supplied with two mounting flanges with stand-offs
(standpipes) used to mount the Transmissometer onto the stack or duct.
1) Each standpipe is 128mm (5.04in) long.
2) Accurately mark the centre of each mounting flange on the stack and
punch a locating mark through the liner onto the inner stack plating.
3) On both sides of the stack, cut a hole from the liner large enough to
allow welding of the mounting flange to the stack.
4) Where the Transceiver will be installed, cut a hole through the stack at
the punched location mark.
5) Where the Retro-Reflector will be installed, make a 6mm to 12mm
diameter pilot hole (0.25in to 0.50in)
A3.3 Maintaining the path length during installation
The installation path length is defined as the distance between the outer
faces of the mounting flanges of the transceiver and retroreflector. This is
somewhat greater than the stack flange-to-flange path length, to allow for
optical alignment. The length of accessories such as spoolpieces or fail-
safe shutters also increases the installation path length relative to the stack
flange-to-flange path length.
The installation path length must be specified at the time of order
and the instrument is factory set for this path length.
The installation path length is indicated on the back of the Transceiver.
During the welding and alignment procedures the flange-to-flange
measurement path must not change by more than ±1%, otherwise the
accuracy of the measurement readings may be affected.
Flange to flange path length
Transceiver
Retro-reflector
Summary of Contents for 4500 MKIII
Page 4: ...Opacity and Dust Monitor User Guide Model 4500 MkIII Preface Blank...
Page 6: ...INTRODUCTION A...
Page 29: ...A 23 Model 4500 MkIII Opacity and Dust Monitor User Guide A4 3 Mounting the AFU APS I O...
Page 41: ...GETTING STARTED B...
Page 42: ...Opacity and Dust Monitor User Guide Model 4500 MkIII Preface Blank...
Page 76: ...THEORY OF OPERATION AND APPLICATION C...
Page 86: ...SYSTEM SPECIFICATION D...
Page 91: ...MAINTENANCE E...
Page 108: ...CHANGING THE INSTALLATION PATHLENGTH F...
Page 113: ...INSTRUMENT RECORD SHEETS G...
Page 114: ...Blank...
Page 117: ...OPTIONAL I O MODULES FOR AFU H...
Page 118: ...Blank...
Page 124: ...LONG PATHLENGTH OPTION App 1...
Page 126: ...Opacity and Dust Monitor User Guide Model 4500 MkIII App 1 2...