![Ametek Land 4500 MKIII User Manual Download Page 23](http://html1.mh-extra.com/html/ametek-land/4500-mkiii/4500-mkiii_user-manual_2931437023.webp)
A - 17
Model 4500 MkIII
Opacity and Dust Monitor
User Guide
A3.11 Cable Specification
Cable types recommended by LAND.
Electrical
Connections
Overview
Nº of
Cores
Core
Size
mm
2
Core Size
strands/
dia
Core
Size
awg
Diameter Screened Supplied
by
1
3
0.5
16/0.2
22
6.5 mm
Yes
LAND
2
8
0.25
7/0.2
24
6.1 mm
Yes
LAND
3
8
0.25
7/0.2
24
6.1 mm
Yes
LAND
4
4
0.5 to
1.5
16/0.2 to
30/0.2
22 to
16
No
Customer
5
3
1.0
32/0.2
18
No
Customer
Cables 1, 2 and 3 are supplied in 5 m lengths.