Networked Indexer/Driver User Manual
ADVANCED MICRO CONTROLS INC.
74
Command Blocks (continued)
Hold Move
Table R7.4 Hold Move Command Block
Unused words are ignored by the Networked Driver and can be any value, including parameter values in the
previous command.
Resume Move
Table R7.5 Resume Move Command Block
Unused words are ignored by the Networked Driver and can be any value, including parameter values in the
previous command. This is typically the case when resuming a move, the words are listed as “Unused” to
highlight that the target position of a held move cannot be changed when the move is resumed.
EtherNet/IP
or PROFINET
Word
Modbus/TCP
Register
Function
Units
Range
0
1024
16#0004
1
1025
2
1026
Unused
See Note Below
3
1027
Unused
See Note Below
4
1028
Unused
See Note Below
5
1029
Unused
See Note Below
6
1030
Unused
See Note Below
7
1031
Unused
See Note Below
8
1032
Unused
See Note Below
9
1033
Unused
See Note Below
EtherNet/IP
or PROFINET
Word
Modbus/TCP
Register
Function
Units
Range
0
1024
16#0008
1
1025
2
1026
Unused
See Note Below
3
1027
Unused
See Note Below
4
1028
Programmed Speed: Upper Word
Steps/Second
Combined value between
the Configured Starting
Speed and 2,999,999
5
1029
Programmed Speed: Lower Word
6
1030
Acceleration
Steps/ms/sec
1 to 5000
7
1031
Deceleration
Steps/ms/sec
1 to 5000
8
1032
Motor Current
0.1 A
SD17060E2: 10 to 60
SD31045E2: 10 to 44
Even numbers only.
9
1033
Acceleration Jerk
0 to 5000