7.5 Set the I/O Configuration
The Networked Drivers require 10 Input Words (20 Input Bytes) and 10 Output Words (20 Output Bytes). All
required Input and Output Bytes are defined by the GSDML file and divided into suitable modules. These set-
tings are shown in the Table T7.1.
Table T7.1 PROFINET I/O Configuration
1) With the SD17060x2 icon selected on the PROFINET bus, click on the “Device view” tab. The view in the
Hardware Catalog will change. Expand the Module tree to show both the Input and Output modules.
2) To map the I/O bytes to the CPU, double click on the “20 bytes IN” and “20 bytes OUT” icons in the
Hardware Catalog. The system will automatically assign the next I and Q addresses to the data table.
Figure T7.4 I/O Byte Mapping
7.6 Verify and Download the New Configuration
1) Continue by adding any remaining devices to your PROFINET network.
2) Compile and download the project to the CPU.
Input / Output Bytes of a
Networked Driver
Input / Output Modules of a
Networked Driver
20 Input Bytes
Input Module - Slot 1: 20 bytes
20 Output Bytes
Output Module - Slot 2: 20 bytes