Networked Indexer/Driver User Manual
ADVANCED MICRO CONTROLS INC.
80
Command Blocks (continued)
Reset Errors
Table R7.16 Reset Errors Command Block
Unused words are ignored by the Network Driver and can be any value, including parameter values in the
previous command. Resetting errors will also reset the
Move_Complete
status bit in the Network Input Data.
Run Assembled Move
Table R7.17 Run Assembled Move Command Block
Unused words are ignored by the Networked Driver and can be any value, including parameter values in the
previous command.
EtherNet/IP
or PROFINET
Word
Modbus/TCP
Register
Function
Units
Range
0
1024
16#0400
1
1025
Set bit 10 to clear
driver faults
2
1026
Unused
See Note Below
3
1027
Unused
See Note Below
4
1028
Unused
See Note Below
5
1029
Unused
See Note Below
6
1030
Unused
See Note Below
7
1031
Unused
See Note Below
8
1032
Unused
See Note Below
9
1033
Unused
See Note Below
EtherNet/IP
or PROFINET
Word
Modbus/TCP
Register
Function
Units
Range
0
1024
16#2000
1
1025
Blend Move: Bit 9 = “0”
Dwell Move: Bit 9 = “1”
Reverse_Blend_Direction
is set by Bit 4.
2
1026
Unused
See Note Below
3
1027
Unused
See Note Below
4
1028
Unused
See Note Below
5
1029
Unused
See Note Below
6
1030
Unused
See Note Below
7
1031
Unused
See Note Below
8
1032
Motor Current
0.1 A
SD17060E2: 10 to 60
SD31045E2: 10 to 44
Even numbers only.
9
1033
Unused with Blend Move
Dwell Time with Dwell Move
milliseconds
0 to 65,535