![Amazone Cirrus 3002 Operating Manual Download Page 77](http://html1.mh-extra.com/html/amazone/cirrus-3002/cirrus-3002_operating-manual_2919743077.webp)
Structure and function
5.9.2
Connecting the blower fan to the tractor's universal joint shaft
A hydraulic pump (Fig. 72/1) is plugged onto the
tractor's universal joint shaft and drives the hy-
draulic motor of the blower fan.
Fig. 72
Set the speed of the tractor's universal joint shaft
to 1000 rpm.
Fig. 73
Tractor universal joint shaft speed: 1000 rpm.
DANGER
Do not exceed the maximum blower fan speed of 4000 rpm.
If required, reduce the universal joint shaft speed in order to reduce
the blower fan speed.
Cirrus BAH0049-1 09.14
77