Fault Conditions
18-8 Maintenance, Servicing and Disposal
See section 15.
18-9 Actions in the Event of an Accident
See section 16.
19. Troubleshooting
20. Index of Error Codes
Where ‘Red LED’ is crossed marked with an “X”, the error number will correspond directly to
the number of blinks of the Red LED.
21. Tech-Air™ Support
In case of questions or if customers need further information, they may first contact the
Tech-Air™ dealer where the product was purchased, however support is also available direct
from Alpinestars:
E-mail: [email protected]
Tel: +39 0423 5286 (asking for Tech-Air™ Support)
Tip: Remember that a full list of Tech-Air™ dealers in your country is available
from the Tech-Air™ Data Portal.
Problem
Possible Cause
Possible Solutions
Vest does not startup when the
activation flaps (18) are closed.
Master Switch not on
Turn on Master Switch (8)
Battery fully discharged
Recharge battery (Section 11)
Suit and vest not connected
Connect LED Display wires to unit (section 8)
Activation flaps open
Close the activation flaps, checking that as they
are closed the magnets attract one another.
Activation Flaps obstructed or not aligned
Check that there is nothing in between the
activation flaps and that the velcro closure is
only used AFTER the magnets have attracted
both parts together.
Single Red Indication on LED
Display
Dependent on error
Consult list of error codes in Section 20 for
recommended solution
Code Number
Red LED Error Description
Possible Solution
001
x
Firmware Error
Reflash Firmware / Return for Service
002
x
Power Supply Error
Recharge Battery / Return for Service
003
x
Battery Voltage Too Low
Recharge Battery
004
x
Reset Squib Error
Restart Unit, if error persists, Return for Service
005
x
Squib Configuration Error
Recharge Battery, Restart Unit, if error persits, Return Service
006
x
Squib Diagnosis Fail
Restart Unit, if error persists, Return for Service
007
x
Inflator 1 error
Restart Unit, if error persists, Return for Service
008
x
Left Sensor Error
Return for Service
009
x
Right Sensor Error
Return for Service
010
x
Central Sensor Error
Return for Service
011
x
Gyro Sensor Error
Return for Service
012
x
Squib Arming Error
Restart Unit, Recharge Battery, if error persists, Return Service
013
x
Synchronization Error
Reflash Firmware / Return for Service
015
x
Load Algorithm Error
Reflash Firmware
018
x
Inflator 2 Error
Restart Unit, if error persists, Return for Service
019
x
Left Sensor Power Supply
Return for Service
020
x
Right Sensor Power Supply
Return for Service
024
x
Algorithm Not Stable
Switch system off and on, sitting on motorcycle
025
x
Unit Locked
Indicates that both charges have been fired
and that the airbag must be replaced.
128
First Charge Activated
No action.
136
Second Charge Activated
Return for service / Dispose of System.
27
EN
RACE
Summary of Contents for Tech-Air
Page 1: ...USER S GUIDE IMPORTANT READ THIS MANUAL SAFETY CRITICAL INFORMATION INSIDE v 1 4 RACE...
Page 2: ......
Page 30: ......
Page 32: ......
Page 60: ......
Page 62: ......
Page 90: ......
Page 92: ......
Page 120: ......
Page 122: ......
Page 150: ......
Page 152: ......
Page 180: ...USER S GUIDE v 1 4 RACE...
Page 181: ......
Page 182: ...Alpinestars Alpinestars Alpinestars RACE...
Page 186: ...7 Tech Air 4 Tech Air Tech Air Tech Air Tech Air Tech Air Tech Air RACE...
Page 188: ...4 9 11a 11b 11c 12 13 14 15 16 LED 17 LED 18 8 9 7 5 6 4 12 17 16 18 10 4 RACE...
Page 199: ...20 Tech Air 10 1 2 3 4 5 f Tech Air download area 18 Tech Air Alpinestars 10 1 2 3 4 5 3 RACE...
Page 204: ...18 4 10 18 5 11 18 6 12 20 60 11a 11a 60 LED 11c 11 Tech Air LED 20 60 11a 25 RACE...
Page 209: ...30 RACE...