Inverter Settings
900-0117-01-00 Rev A
83
Battery Charger
IMPORTANT:
Battery charger settings need to be correct for a given battery type. Always follow battery manufacturer
recommendations. Making incorrect settings, or leaving them at factory default settings, may cause the
batteries to be undercharged or overcharged.
The inverter uses a “three-stage” battery charging cycle which utilizes multiple settings. This menu
controls the voltages and timers for the battery charger. See the inverter
Operator’s Manual
for an
explanation of the three-stage cycle and a description of the individual stages.
In a grid-interactive model, the Sell voltage setting is used as part of the charging cycle. That voltage is
not accessible here, but is settable in the
Grid-Tie Sell
menu (see page 90). The Equalize settings are also
not accessible here, but are settable in the
Battery Equalize
menu (see page 84).
To access the Battery Charger menu:
1.
Access the
Inverter
menu as shown in Figure 71 on page 75.
2.
Use the control wheel to highlight the
Battery Charger
menu.
Press the button in the center of the control wheel to accept the selection.
3.
Use the control wheel to increase or decrease the set points to the correct voltage.
Press the button in the center of the control wheel to accept the selection.
This should automatically move the highlighting to the next set point.
Repeat for each set point.
4.
After setting the parameters for each set point, press the
TOP
navigation key to return to the
Main Menu
screen.
Figure 78
Battery Charger
Set Points:
Absorb Voltage:
Adjusts the target voltage of Bulk and Absorption stages.
(Absorb)
Time:
Adjusts the duration of the Absorption stage.
Float Voltage:
Adjusts the target voltage of the Float stage.
(Float)
Time:
Adjusts the duration of the Float stage, once the voltage has been reached.
Re-Float Voltage:
Adjusts the point at which the Float stage begins again.
Summary of Contents for OutBack Power MATE3
Page 1: ...MATE3 System Display and Controller Owner s Manual ...
Page 22: ...Installation 20 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 142: ...Troubleshooting 140 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...Specifications 142 900 0117 01 00 Rev A NOTES ...
Page 159: ......