Operation
54
900-0117-01-00 Rev A
AC INPUT Hot Key
The
AC INPUT
hot key displays the
AC Input Status
screen. The
AC Input Status
screen displays the AC
input mode, the AC input status, and the current AC frequency and voltage. Soft key options include
manually using or dropping the AC input source or viewing the
Last AC Disconnect
screen. The
Last AC
Disconnect
screen indicates the reason the AC source may have been disconnected.
Figure 48
Using the AC INPUT Hot Key
Figure 49
Disconnect Reasons
Soft Key Options:
<Back>
returns to the
AC Input Status
screen.
<
Port
> cycles through all the devices
connected to the HUB.
AC INPUT Hot Key
Soft Key Options:
<Back>
returns to the Home screen.
< Drop>
manually disconnects the system from the AC source.
< Use>
instructs the inverter to use the AC source if the AC
source meets qualification parameters.
<Discon>
displays a screen that shows the reason for the last
AC disconnect .
Screen Items:
AC Input Mode
allows soft key options to be
selected to change the mode. This item may
be overridden by other commands. For
example, a system that is set to
DROP
will
automatically switch to
USE
if AGS starts the
generator.
AC Input Status
displays the current
interaction with the AC input. This screen
will usually change to match
AC Input Mode
once a soft key command is given.
Summary of Contents for OutBack Power MATE3
Page 1: ...MATE3 System Display and Controller Owner s Manual ...
Page 22: ...Installation 20 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 142: ...Troubleshooting 140 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...Specifications 142 900 0117 01 00 Rev A NOTES ...
Page 159: ......