NetEnforcer AC-1000 Hardware Guide
4-1
Chapter 4: Redundancy
Enabling Redundancy
In order to implement redundancy, it is necessary to configure the network interfaces
and enable redundancy in each NetEnforcer involved.
Configuring the AC-1010 via the NetEnforcer
1.
Configure the Management Port interface via the LCD on the front panel of the
NetEnforcer.
2.
Log into the NetEnforcer via the Management Port or Telnet (see page 3-1).
3.
Open a console connection to the NetEnforcer and use the following CLI
commands:
To set the interfaces:
go config nic
•
Options are:
o
internal1 MODE:SPEED
o
external1 MODE:SPEED
For example:
go config nic –internal1 full:100