Chapter 1: AC-1000 Series Hardware
NetEnforcer AC-1000 Hardware Guide
1-28
4.
Connect a 62.5/125
μ
or 9/125
μ
Internal fiber optic cable from the Internal port on
the Bypass Unit to a 1 Gbps switch.
5.
Repeats Steps 1 to 4 for Link 2.
6.
Connect the D-type High Density connector from the Primary port on the Bypass
Unit, to the Backup port on the Primary NetEnforcer. The 9-pin connector is
plugged into the bypass unit and the 26 pin connector is plugged into the
NetEnforcer.
NOTES
To connect a secondary NetEnforcer for Parallel Redundancy, you need
two NetEnforcers and one Bypass Unit.
Internal and external connectors of the redundant NetEnforcer should be
connected directly to the network. There is no need to connect via the
Bypass Unit.
AC-1040 Bypass Unit
Multi-Port Copper Bypass Unit
The Multi-port Copper Bypass Unit works in conjunction with the NetEnforcer AC-
1040 Copper.
Figure
1-17 – Multi-Port Copper Bypass Unit
NOTE
Use UTP CAT-6 straight Ethernet cables to connect link connections
marked with Internal and External labels. The maximum Ethernet cable
length is generally 50 meters.
The Copper Bypass Unit includes RJ-45 connectors for Ethernet cables and D-type
9-pin connectors for primary and redundant unit to backup connection.