Publication 1747-6.5.5 - August 2000
Creating and Running the Example Application Program
6-7
6.
Double-click on the
O0 - OUTPUT
file under the
Data Files
folder.
You will see the 1747-SDN module’s command register (file O:2.0
below).
7.
Set bit 0 in the command register to "1", as shown above.
8.
Press and release the
START
button on the RediSTATION. The red
light should turn on. On your screen, you will see rung 1 in your
ladder program being energized as you press the button.
9.
Pass your hand back and forth over the photoeye several times. On
your screen you should see the counter increment.
10.
Press and release the
STOP
button on the RediSTATION. The red
light should turn off. On your screen, you will see rung 2 in your
ladder program being energized as you press the button.
This completes the Ethernet example.
IMPORTANT
You must also place the 1747-SDN scanner in run
mode by setting the Run Bit (bit 0) in the scanner’s
command register. The command register is located
at word 0 in the Output image table.
Summary of Contents for SLC 500 DeviceNet
Page 1: ...SLC 500 DeviceNet Scanner Module 1747 SDN User Manual...
Page 4: ......
Page 52: ...Publication 1747 6 5 5 August 2000 3 16 Hardware Setup...
Page 68: ...Publication 1747 6 5 5 August 2000 4 16 Configuring the DeviceNet Network...
Page 86: ...Publication 1747 6 5 5 August 2000 5 18 Communicating with DeviceNet from Another Network...
Page 96: ...Publication 1747 6 5 5 August 2000 6 10 Creating and Running the Example Application Program...
Page 106: ...Publication 1747 6 5 5 August 2000 A 6 Data Map Example...
Page 118: ...Publication 1747 6 5 5 August 2000 E 4 Configuring SLC 5 05 Ethernet Communications...
Page 128: ...Publication 1747 6 5 5 August 2000 G 4 Installing and Configuring the DH Communications Driver...
Page 137: ......