Remote control commands
R&S
®
NGU
142
User Manual 1179.2531.02 ─ 03
7.5.8
Source priority mode setting
SOURce:PRIority
<arg0>[, <Channel list>]
SOURce:PRIority?
<arg0>[, <Channel list>]
Sets or queries the source priority mode.
Parameters for setting and query:
<arg0>
VOLTage | CURRent | <list>
VOLT
Set the source measure unit to operate in voltage priority mode.
CURR
Set the source measure unit to operate in current priority mode.
<Channel list>
<list>
Example:
SOUR:PRI?
-> CURR
Example:
SOUR:PRI? (@1)
Queries the operating mode of the source measure unit at chan-
nel 1.
7.5.9
Modulation input
Available only with R&S NGU401 model.
[SOURce:]MODulation
<arg0>[, <arg1>]
[SOURce:]MODulation?
<arg0>[, <arg1>]
Enable/disable modulation of DVM input onto the output signal.
Parameters for setting and query:
<arg0>
<arg1>
<list>
Example:
MOD 1
Enable modulation of DVM input onto the output signal.
[SOURce:]MODulation:GAIN
<arg0>[, <arg1>]
[SOURce:]MODulation:GAIN?
<arg0>[, <arg1>]
Sets or queries the modulation gain.
Parameters for setting and query:
<arg0>
<numeric value> | MIN | MINimum | MAX | MAXimum | UP |
DOWN | <list>
<numeric value>
Numeric value of the modulation gain.
Configuration commands
www.allice.de
Allice Messtechnik GmbH