GB 00754 - Edition 08 - Januar
y 04
D 20
Alcatel Vacuum Technology France - User’s Manual ATH 1300 M/MT - ATH 1600/M/MT
Diagnosis and troubleshooting
5/8
N
Y
N
N
N
INCIDENT
CAUSE
CONSEQUENCE
REMEDY
W 28:
DISABLE
EEPROM WRITE
D 29:
INPUT POWER
D 30:
EEPROM
CHECKSUM
D 31:
CODING
D 32:
C. INSIDE
Memory problem.
Main power failure.
Memory erased.
Incompatibility between
the pump and the
controller.
Controller inside wiring
disconnected.
The controller doesn’t
stop the motor and
the data is not saved.
Imminent landing.
The pump doesn’t start.
The pump doesn’t start.
The pump doesn’t start
■
Reinitialize the controller with
main switch 0/1 when the pump
is stopped.
■
If the fault appears again,
contact the Customer Service.
■
Check that the power supply is
present, otherwise see
D 20 7/8;
■
Contact the Customer Service.
■
Contact the Customer Service.
■
Replace the pump model or
controller:
ATH 2300 M and ACT 2300 M,
or
ATH 1300 M and ACT 1300 M.
or
ATH 1600 M and ACT 1300 M.
FAULT
OPEN
■
Check that the cable between
pump and controller is correctly
connected.
■
Replace the pump model or
controller:
ATH 2300 M and ACT 2300 M, or
ATH 1300 M and ACT 1300 M, or
ATH 1600 M and ACT 1300 M.
■
Pump stopped, switch off the
controller and start again;
■
Contact the Customer Service
Several defects appear:
I
NCIDENT
C
AUSE
R
EMEDY
D 04 - D 05 - D 11
D 25 - D 26 - D 31
The pump is not connected to
the controller.
D 11 - D 31
Incompatibility between the
pump and the controller.
D 04 - D 05
Motor information failure.
Summary of Contents for Adixen ATH 1300 M
Page 1: ...ATH 1300 1600 M MT MAGLEV HYBRID TURBOMOLECULAR PUMPS User s Manual...
Page 24: ......
Page 26: ......
Page 32: ......
Page 44: ......
Page 50: ......
Page 62: ......
Page 64: ......
Page 68: ......
Page 70: ......
Page 82: ......
Page 88: ......
Page 96: ......
Page 98: ......
Page 112: ......
Page 114: ......
Page 116: ......
Page 122: ......