13-7
TROUBLESHOOTING
SM CKDDCI 2-A.3 GB
No
Problem
5
4
3
2
1
1
OCT is disconnected
0
0
0
0
1
2
OCT is shorted
0
0
0
1
0
3
CTT is disconnected
0
0
0
1
1
4
CTT is shorted
0
0
1
0
0
5
HST is disconnected (when enabled)
0
0
1
0
1
6
HST is shorted (when enabled)
0
0
1
1
0
7
OAT is disconnected
0
0
1
1
1
8
OAT is shorted
0
1
0
0
0
9
OMT is disconnected
0
1
0
0
1
10
OMT is shorted
0
1
0
1
0
11
IPM Fault
0
1
0
1
1
12
Bad EEPROM
0
1
1
0
0
13
DC under voltage
0
1
1
0
1
14
DC over voltage
0
1
1
1
0
15
AC under voltage
0
1
1
1
1
16
IDU/ODU Communication mismatch
1
0
0
0
0
17
No Communication to IDU
1
0
0
0
1
18
No Communication to Driver
1
0
0
1
0
19
Current sensor Fault
1
0
0
1
1
20
Heat sink Over Heating
1
0
1
0
0
21
Deicing
1
0
1
0
1
22
Compressor Over Heating
1
0
1
1
0
23
Compressor Over Current
1
0
1
1
1
24
OFAN_UP error
1
1
0
0
0
25
OFAN_DN error
1
1
0
0
1
26
Compressor Lock
1
1
0
1
0
27
Bad Communication
1
1
0
1
1
28
High pressure protection
1
1
1
0
0
29
Low pressure protection
1
1
1
0
1
30
Reserved
1
1
1
1
0
31
Reserved
1
1
1
1
1
1 - ON, 0 - OFF
Only one code is shown. Order of priority is lower to the higher number. Diagnostics is continuously
ON as long power is on.