12-15
CONTROL SYSTEM
SM CKDDCI 2-A.3 GB
12.4.6.3 Sequence
Diagrams
Reduce room humidity with minimum temp. fluctuations by operating in Cool Mode with
LOW speed IFAN.
min{
MaxNLO ExtraNLOADDry
,127 }
RAT-SPT
IFAN Low
0
IFANOnTimeDry
MaxNLOADIF1C
NLOAD
ICTLowLimitDry
ICTHighLimitDry
Note 1
IFANOffTimeDry
Note 1
NLOAD
0
Note 1
Min(ICT,ICTE)
1
12.4.7 Sleep
Mode
12.4.7.1 Sleep Mode - General
a. Mode
Definition
Mode: Any
Temp: Selected desired temperature
IFan: Any
Timer: See
below
I-FEEL: ON or OFF
12.4.7.2 Control
function
The Sleep mode is activated by using the SLEEP button on the R/C. In Sleep
o
Mode, the unit will automatically adjust the SPT to turn up/down the room
temperature (RT) gradually to provide maximum comfort for the sleeping user.
Sleep is treated as TIMER function. Therefore, the TIMER LED is activated similar
o
to TIMER function.
In COOL, AUTO COOL or DRY modes, the SPT adjustment is positive
o
(from 0 to +3
o
C).