INTRODUCTION
SM CKDDCI 2-A.3 GB
1.
INTRODUCTION
1.1 General
The new
GCD 036 DCR, GC 36-43 DC INVERTER
split unit range comprises the
following RC (heat pump) models:
•
CKD 036
•
CKD 045
Remote control compatibility
The
units are compatible with remote controls RC3, RC4, RCW1, RCW2, RC7.
Inverter description
Unlike standard units (fix RPM) that are selected according to their nominal capacity to
overcome the maximum required load, DC Inverter units can be selected to a smaller
nominal capacity range unit.
It made possible due to the ability of inverters to reach a much higher capacity level
(indicated as Maximum Capacity) which is around 115-130% of the nominal capacity.
1.2 Main
Features
High Technology
•
Sine wave DC Compressor drive.
•
DC-BL-SL (DC Brush-Less Sensor less) Inverter Compressor.
•
DC-BL Inverter Outdoor Fan.
•
Fuzzy Logic Adaptive Control.
System Features
•
Variable cooling and heating capacity from 30% to 115% (of rated capacity).
•
High COP “A-B” class energy rating (Most units).
•
Low noise levels.
•
Pre-charged system up to 30m.
•
Tubing up to 70m length / 30m height difference.
•
Networking
connectivity.
•
Current limitation setting for circuit breaker size reduction (if required).
•
Dry contact inputs:
♦
Standby.
♦
Night mode (for silent operation in cooling).
♦
Power Shedding (to control maximum power consumption).
•
Dry contact output:
♦
Alarm
♦
Base Heater
♦
Crank Case Heater
•
HMI Display consists of 7-segments shows system diagnostics and setup.
•
Monitoring software (PC port for high level service).
•
Cooling operation at outdoor temperature down to -10°C.