53 © 2012 Agricultural Instruments Corporation
(AIC) 608.526.6882
#20560 Diaphragm Pulsator Solenoid Valves:
Specifications:
Input power
—
Nominal 24 VDC regulated power.
Current Draw—
20mA at 24 VDC
Solenoid Coil Resistance—
1.1K to 1.2Kohms
Servicing the Diaphragm Style Pulsator: (Solenoid Replacement)
The pulsator solenoid valves have a low current draw (20mA), enabling relatively small power
supplies to be used. The solenoid coil resistance should be within the range of 1.1k to1.2k ohms.
If outside of this range replace the coil by disconnecting the power wires and puling the solenoid
out of the snap bracket. Replace with a new 20504 Replacement Solenoid Coil.
******Wire polarity is non
-
specific******
90020504
Replacement
Solenoid Coils
Pulsator Specifications and Servicing
Checking the Solenoid Coil Re-
sistance
1)
Using a Volt meter, turn it on the
ohms (horse shoe)
2)
Check the Resistance between
the outside Black and Red wires.
(SEE DIAGRAM BELOW)
3)
Make sure the resistance range is
correct 1.1k
-
1.2 k ohms.
STEP TWO