Expresso Tie Stall
26 © 2012 Agricultural Instruments Corporation
(AIC) 608.526.6882
Page 1
Languages
Allows you to choose the language you which the control to display.
ID Enable
Moving ID enable to yes makes the 72560 units ask for a cow ID number when the right switch is
pressed to start milking. The ID prompt will occur at this time. To enter an ID number press the
right switch to scroll to the correct number and press the left switch to move the curser to the next
number.
Units of Measure
Allows you to choose the unit of measure desired. You can choose Kg/Centigrade or LB/
Fahrenheit.
Take off Flow Rate and Take off Delay
These two adjustments are used to determine when the end of milking signal will occur. Adjust
these settings to increase or decrease milking unit on time. (For dry or wet milk out)
Maximum Milking Time
This setting allows you to establish a maximum milking time. The detacher will detach the claw no
matter of the milking status of the cow or the detacher set
-
up mode i.e. manual or automatic.
Conductivity Delay
The amount of first milk the detacher ignores before it starts to measure the conductivity of the
milk.
Milk Letdown Delay
The letdown delay occurs at each attach and causes the detacher to remain attached in the
absence of milk flow. The purpose of the delay is to give the operator time to attach the milking unit
to the cow, and give the cow adequate time let down her milk without the detacher retracting early.
If the unit is in the automatic mode at the end of the delay period, and she has not let down her
milk, the unit will retract and the NO MILK lights will flash to indicate an early detach (see early
detach in the automatic mode). Letdown Delay is adjustable (see Control
’
s Set
-
up Table)
Vacuum On Delay
This setting alters the amount of time between the
“
Attach
”
start and the shutoff valve opening. It
can reduce the amount of debris entering the claw and help stabilize the system vacuum.
Setup Definitions