Expresso Tie Stall
22 © 2012 Agricultural Instruments Corporation
(AIC) 608.526.6882
Function
Range
Increments
Factory
Settings
Effects of Adjustments
Page 4
Use CT Logic
Yes/No
No
CTLogic Average
4,8 or 16
4
The number of cow milk
temperatures that are averaged.
The average is considered the
normal milk temperature.
CTLogic Deviation
.3
–
5.9
Degrees
2 Degrees
The deviation degree is the
amount the milk temperature must
deviate from the average to set
-
off
the high temp. alarm.
Alarm Temperature
Threshold
100
-
108 F
37.7 to 42.2 C
.1 Degrees
102.6 F
39.2 C
Adjust milk temperature alarm to a
fixed threshold. If a temperature
exceeds , will alarm.
Calibrate Temp.
Degrees F or C
(=
-
60) to (=60)
.2 Degrees
.1 Degrees
*F
*C
*F/*C are the current temperature
of the flow cell
Wash Temperature
Threshold
109.4 to 130 F
.2 F
120 F
Set this setting to the threshold,
wash water temperature desired
before the Expresso starts tracking
time over this temperature
threshold .
Graph Time
6.4, 9.6, 12.8 16.0
Minutes
9 Minutes
The selected minutes, determines
the horizontal axis of the graph.
Lowering the minutes enhances
the resolution of the graphics.
Control Set Up