Expresso Tie Stall
41 © 2012 Agricultural Instruments Corporation
(AIC) 608.526.6882
The Expresso Detacher
™
Control stores milking data for each individual milking.
To review the data in memory: Press
“
Gear
”
Key then select 1 Review Data
See the above Summary Screen.
Averages
-
The first data under the review data display is an average yield for the valid completed
milkings. The average pounds
-
of
-
milk is the total pounds of milk divided by the number of milkings
(in 00 milkings).
Total –
Total Pounds (or Kilograms)
-
The total milk stored in memory.
Milkings
-
is the total number of valid milkings that have been completed. The maximum number of
stored milkings is 60. Once the Control reaches 60 milkings, the
“
First In Last Out
”
storage applies.
That is, the first record in is added to the top of the data list and the last record is removed.
To enter into the Setup Mode, press
“”
Gear
”
Key then select 2 for set
-
up.
Once in the Setup Mode, see Expresso Switch Operation
ATTACH COUNT = 141
Vac On Time
TOTAL 703 LB
AVERAGE 22.7 LB
IN 31 MILKINGS
EXIT:0
NEXT: 9
Lifetime Attachments
Lifetime hours of operation
Number of the last
current Milkings:
Maximum of 60
milking
To EXIT, press the left
Auto/Manual switch
Press NEXT to continue
to review Data
Average production per
milking i.e. 703/31=22.7
Total milk i.e. total milk of
the milkings in memory,
maximum of 60 milkings
72560 Summary Screen
Reviewing Milking Data