R3132 Series Spectrum Analyzer Operation Manual
3.3.18 POWER MEASURE Key (Power Measurement)
3-61
CS/BS Setup
Displays the CS/BS Setup menu, and the editor used to set the
channel space and channel bandwidth together.
√
Nyquist Filter ON/OFF
Toggles the
√
Nyquist filter function on or off.
ON:
Turns the Nyquist filter function on.
OFF:
Turns the Nyquist filter function off.
Insert Line
Inserts a line in the cursor position.
Delete Line
Deletes the line at the cursor position.
Sort
Sort the CS/BS Setting table by CS.
Table Init
Deletes all data in the table.
BS Window ON/OFF
Toggles the ACP bandpass window display on or off.
ON:
Displays the window within the bandpass which is tar-
geted for calculating the ACP.
OFF:
Removes the window.
√
Nyquist Filter Setup
Displays the
√
Nyquist Filter Setup dialog box.
Symbol Rate 1/T
Sets the symbol rate.
Rolloff Factor
Sets the rolloff factor.
√
Nyquist Filter
Toggles the Nyquist filter function on or off.
ON:
Turns the Nyquist filter function on.
OFF:
Turns the Nyquist filter function off.
Results REL/ABS
Toggles the unit of the measurement result display.
REL:
Displays a relative value (dBc) of the power within the
carrier bandwidth (set by CS/BS editor and referred to
as the Ref Power) to the ACP power.