Setup the Digital Input (DI) Profile rules. It supports up to a maximum of 10 profiles.
Figure 3.177 Service > Event Handling > Configuration > Digital Input (DI)
Profile List
When
Add
button is applied, the
Digital Input (DI) Profile Configuration
screen
appears.
Figure 3.178 Service > Event Handling > Configuration > Digital Input (DI)
Profile Configuration
The following table describes the items in the previous figure.
Item
Description
DI Profile Name
Specify the DI profile name.
Value Range: 1 ~ 32 characters.
Description
Specify a brief description for the profile.
DI Source
Specify the DI source. It could be
ID1
or
ID2
. The number of
available DI source could be different for the purchased product.
Continues Update
Status
Click
Enable
checkbox to enable the function. Specify the interval
for the DI event. If the event condition is active for an extended
period of time, the gateway sends repeated notification events for
each interval.
Value Range: 0 ~ 86400 seconds.
Note:
To modify the number of notifications for the same situation,
adjust the interval period for the application.
Normal Level
Specify the normal level. It could be
Low
or
High
.
Signal Active Time
Specify the signal active time.
Value Range: 1 ~ 10 seconds.
Profile
Click
Enable
checkbox to activate this profile setting.
Save
Click
Save