167
–
+
+
-
N.C.
N.C.
N.O.
2k EOLR
(note 1)
2k EOLR
(note 1)
+
-
+
-
+
-
BELL
SIREN
NO CONNECTION
TRANSFORMER
16.5VAC, 40VA
Connect to 24hr.
120VAC, 60 Hz
or
220VAC, 50 Hz
Red
Blk
Grn
Yel
REMOTE KEYPADS
Use 6139
ADDRESSABLE DEVICES
(e.g. 4204, 5881, 5882EU)
+
+
-
N.C.
N.C.
2k EOLR
(note 1)
2k EOLR
(note 1)
+
+
-
N.C.
+
+
-
N.C.
N.C.
2k EOLR
(note 1,4)
TIP
(BROWN)
RING
(GRAY)
TIP
(GREEN)
RING
(RED)
Handset
Connections
Incoming
Phone Line
Connections
EARTH GROUND
Connect to good earth
ground to maintain immunity
to transients. See Instructions
for proper grounding.
SMOKE
4190
RPM
4278EX
PIR
Polling loop rating: 128mA
maximum. See Installation
Instructions for maximum
number of devices supported
and maximum wire run length.
ZONE RESISTANCE (Excluding EOLR):
ZONE 1,8: 100 OHMS maximum
ALL OTHER ZONES: 300 OHMS maximum
ZONE 1
ZONE 2 ZONE 3
ZONE 4 ZONE 5
ZONE 6 ZONE 7
ZONE 8 ZONE 9
2-WIRE SMOKE
DETECTOR LOOP
(Also supports NO/NC Burg contacts)
POLLING LOOP
Programmable Response
(Fast/Normal) Loop
LATCHING TYPE GLASS
BREAK DETECTOR LOOP
Data in
Data out
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
RED (+)
BLK (-)
Connect to
12VDC, 4AH
or 12VDC, 7AH
GEL CELL
BATTERY
CHARGING
VOLTAGE
13.8VDC
See
Installation
Instructions for
required
capacity
NOTE:
WHEN POWERING UP
THE PANEL, CONNECT TO AC
MAINS BEFORE CONNECTING
THE BATTERY.
See Installation Instructions
for max # of keypads
and for max wire run length.
ALARM SOUNDER OUTPUT
10VDC - 13.8VDC 2.8A maximum
(10.7VDC - 14.5VDC for VISTA-120FR)
AUXILARY POWER OUTPUT
9.6VDC - 13.8VDC,
750 mA maximum
Note: Include current drawn
by keypads and polling loop
devices when making
auxiliary power calculations.
+
-
NOTES: 1. Zone 1 may be selected for EOLR supervised
or normally closed (no EOLR) operation via
cut jumper. (Cut red jumper for normally closed
operation. Do not cut for Fire Usage). Zones 2-8
may be selected for either operation via program
field *41.
Zone 1 supports 2-wire smoke detectors.
See Installation Instructions for recommended type
and maximum number of detectors supported.
2.
Zone 7 may be used for remote keyswitch
arming/disarming.
See Installation Instructions for wiring
instructions.
3.
Zone 8 supports 2-wire latching type glass
break detectors.
See Installation Instructions for recommend-
ed type and maximum number of detectors
supported.
4.
1 2 3 4 5 6 7 8 9
1. Not Used
2. Ground-
3. Out 1 (Ground Start)
4. Ground-
5. Out 2 (fire)
6. Ground-
7. Out 3 (burg/aud. panic)
8. Ground
9. Out 4 (silent panic/
duress)
Optional programming:
Out 1: Open/close or keypad-like sounding
Out 2: Armed LED, Fire, CPU Fail
Out 4: Ready LED
Ratings for Out 1:
Active: 10VDC-13.8VDC through 4k OHMS
Not Active: 100 OHMS to ground
Ratings for out 2-4:
Active: 10VDC-13.8VDC through 5k OHMS
Not Active: 1k OHMS to ground
N.C.
N.O.
N.O.
N.O.
2k EOLR
(note 1,2)
N.O.
N.O.
N.O.
N.C.
N.O.
2k EOLR
(note 1)
2k EOLR
(note 1,3)
N.C.
+
-
J7
GLASS
BREAK
1 2 3 4 5 6 7 8 9
J8
MAKE CONNECTIONS USING
No. 4142TR CABLE
Fire
Usage
Burglary
Usage
1. I n 2 (Printer DTR)
2. Ground
3. In 3 (X - 10 sync)
4. In 4 (X - 10 sync)
5. Ground
6. Out 5 (X - 10 data)
7. Out 6 (Printer RXD)
8. Ground
9. Ground
Red Jumper
(note 1)
J7 Header J8 Header
BATTERY
TABS
4192SD
SMOKE
WARNING: TO PREVENT
RISK OF ELECTRICAL
SHOCK, DISCONNECT
TELCO JACK BEFORE
SERVICING THIS PANEL.
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM.
ZONE RESPONSE TIME:
ZONES 1-8: 350mSec-500mSec
ZONE 9: Programmable for
Fast: 10mSec-15mSec
Normal: 350mSec-500mSec
(default response)
(Refer to Installation Instructions for information concerning Direct Wire
Downloading and printer connections using the 4100SM Serial Module.)
ALL CIRCUITS ARE
POWER LIMITED.
VIST
A-
120
SU
MMAR
Y O
F
CO
NN
ECT
IO
N
S DIAG
R
A
M