– 51 –
1 2
3
4
5
6
7
8
9
GRAY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
GROUND
OUT 1
GROUND
OUT 2
GROUND
OUT 3
GROUND
OUT 4
J7 CONNECTOR
IF USED.
1. OUT 1 IS NO LONGER
USABLE FOR OPEN/CLOSE
OR GROUND START (SEE
FIELD 1*46).
2. OUT 2, 3, 4 CAN STILL BE
USED TO PROVIDE ALARM
STATUS INDICATIONS OR
TO OPERATE A KEYSWITCH
(SEE FIELD *15).
N/U
4142TR CABLE
BLACK
–
AMSECO PAL-328N
PIEZO SOUNDER
+
RED
TO AUX POWER +
TERMINAL 6
(10mA CURRENT DRAIN)
Figure 22. Remote Keypad Sounding Connections
Keyswitch Setup
If using an optional Remote Keyswitch for remote arming and disarming of the
system, its switch must be connected to Zone 7 and its Ready and Armed status
LEDs must be connected to the trigger outputs and programmed in order to
become operational.
Note that a zone 7 keyswitch may be used in one partition only.
The keyswitch must be connected to Zone 7, which is then no longer available as
a protection zone. A momentary short across this zone will arm the partition in
the "AWAY" mode. If the short is held for more than 3 seconds, the partition will
arm in the "STAY" mode. After the partition has been armed, the next time Zone
7 is shorted, the partition will disarm.
1.
Connect the 4146 keyswitch's normally open momentary switch to Zone 7.
2.
Connect a 2k EOL resistor across the switch regardless of whether or not
zones 2-8 are selected to use EOL resistors.
3.
Connect the keyswitch Armed and Ready LEDs to the J7 connector as shown.
4.
Connect an optional closed circuit tamper switch (ex. No. 112) in series with
zone 7.
5.
Assign the keyswitch to its appropriate partition in programme field *15.
Enable open/close reporting (user #0) for the keyswitch in field *40 (if
desired).
NOTE:
When the keyswitch is
removed from the wall, the
tamper switch will open causing
a fault (trouble or alarm) on
zone 7 and causing the panel
to disable keyswitch operation
until the partition is disarmed
from a keypad.
RED
820ohms
YELLOW
RED
(ARMED)
BLACK
820ohms
WHITE
GREEN
(READY)
BROWN
BROWN
BLUE
BLUE
LOCK SWITCH
(NORMALLY OPEN)
2K EOLR
TAMPER SWITCH
TO AUX POWER
(TERMINAL 6)
TO J7/OUT 2
TO ZONE 7(+)
(TERMINAL 20)
TO ZONE 7(– )
(TERMINAL 19)
TO J7/OUT 4
BROKEN LINES REPRESENT
INSTALLER WIRING CONNECTIONS
Figure 23a. Remote Keyswitch Wiring
LED indications are defined as follows:
Green Red
Meaning
Off
Off
Disarmed & Not Ready
On
Off
Disarmed & Ready
Off
On Steady
Armed Away
Off
Slow Flash
Armed Stay
Off
Rapid Flash
Alarm Memory