- 141 -
CONTROL/COMM ACCESS:
Read Only: able only to Upload and arm the system. Not able to
DISARM, BYPASS, or change any information.
Part Read/Write: able to ARM, BYPASS, UPLOAD, DOWNLOAD but
cannot shutdown the system.
Full Read/Write: able to perform all control and status commands, as
well as shutdown all or part of the system.
NOTES:
1.
Each time the Control panel is accessed successfully, a PROGRAMME
TAMPER report (*81) is sent to central station, if programmed.
2.
When downloading, the keypad displays "MODEM COMM."
3.
Whenever a download or a save is done, an automatic time stamp is done,
indicating the date and time of the last download (or save) and the
operator ID number.
4.
The average time for a complete download, including initial call-up,
hang-up and call-back is under 4 minutes.
5.
A complete hard copy of each individual account can be obtained by
connecting a printer to the computer. Refer to your computer owner's
manual or contact your distributor for printer recommendations.
Connecting a
4100SM Module
for Direct Wire
Downloading
The Control can be downloaded without using a modem or telephone line by using
VLINK® Software and a 4100SM Serial Module. The direct wire downloading
connection is to be temporary, and is not part of the permanent installation. Direct
wire downloading is meant as a tool for the installer during the installation
process.
The connections between the Control and the 4100SM are different than those
shown in the 4100SM Installation Instructions. See the diagram below for correct
connections. In addition, when the "green" wire is referred to in step 2 of the IN CASE
OF DIFFICULTY section of the 4100SM Instructions, use the "violet" wire.
Connector J8, located above connector J7 on the right hand side of the main PC
board (see the Summary of Connections diagram on the inside back cover of this
manual), is intended to be interfaced to either a local serial printer (see EVENT
LOG PRINTER CONNECTIONS) or a computer. Make connections to a
computer as shown below. Note that the violet wire connection for a
computer differs from that used when connecting a serial printer.
1
2
3
4
5
6
7
8
9
NU
J8 CONNECTOR
VIOLET
GRAY
YELLOW
RED
GREEN
BROWN
BLUE
BLACK
IN 2
GROUND
IN 3
GROUND
OUT 5
OUT 6
GROUND GROUND
P
R
IN
TER
D
TR
4142TR CABLE (SUPPLIED WITH 4100SM)
8
7
6
5
4
3
2
1
4100SM SERIAL MODULE
+ PWR
- (GND)
RXD
not used
not used
TXD
not used
not used
RED BLUE WHITE
To TB6 Aux. Power (+)
(25mA current draw)
To TB7 Aux. Power (-)
Figure 31: Direct Wire Downloading Connections