– 150 –
SECTION 27
Keypad Functions
This section provides the following information:
• General information about keypad usage
• Basic keypad functions
• Global arming
• Access control
• Delaying closing time
• Executing the "Go To" command
• Viewing:
Built-in user's guide
A user's capabilities
Zone descriptors
Downloaded messages
• Speed keys' macro commands
• Executing #70 Manual Relay Activation mode
General
Information
The keypad allows the user to arm and disarm the system, and perform other system
functions, such as bypassing zones, viewing messages from the central station, and
displaying zone descriptors. Zone and system conditions (alarm, trouble, bypass) are
shown in the display window.
When an alarm occurs, keypad sounding and external sounding will occur, and
the zone(s) in alarm will be displayed on the keypad. If the alarm display lock
feature is enabled (field 1*10), the first zone to go into alarm is displayed.
Pressing the [T] key will display other zones in an alarm state. Pressing any key
will silence the keypad sounder for 10 seconds. Disarming the system will
silence both keypad and external sounders. When the system is disarmed, any
zones that were in an alarm condition during the armed period will be displayed
(memory of alarm). To clear this display, simply repeat the disarm sequence
(enter the security code and press the OFF key).
The keypads also feature chime annunciation, and 3 panic keys (for silent,
audible, fire or personal emergency alarms) which can notify the central station
of an alarm condition, if that service is connected.
To protect the system against repeated code entry attempts to find a valid user
code, code entry of more than 20 key presses within a 15 minute period without
successful entry of a valid command sequence will result in a 15 minute lockout
of all keypad entries within this keypad's partition.
Arming Functions
The following is a brief list of system commands. For detailed information concerning
system functions, refer to the User's Manual.
Display Faulted
Before arming, the system must be in the READY condition
(all zones
Zones
must be intact). If the "NOT READY" message appears,
press the READY
✴
key to display faulted zones.
Arming Away
Enter code + 2 (AWAY) .
Arming Stay
Enter code + 3 (STAY) . (all zones designated as zone types
4 and 10 will be automatically bypassed)
Arming Instant
Enter code +
7 (INSTANT) (same as STAY without entry delay)
Arming MaximumEnter code + 4 (MAXIMUM) (same as AWAY without entry delay)
Disarming
Enter code + 1 (OFF) .