Example of Open/Close Exception Reporting & Scheduling
6:01PM
5:59AM
6AM
9AM
9:01AM
3:59PM
4PM
6PM
6:01PM
5:59AM
"Early opening" reports
Opening Window Auto-disarm delay begins .
Closing Window Auto-arm delay begins
will be sent if system
No reports sent
Auto-disarm occurs after delay.
No reports sent
Auto-arm warning begins.
is disarmed before
if system disarmed
(if auto-disarm is enabled)
if system armed*
Auto-arm occurs after
opening window begins. during this time
during this time
warning expires.
window.
"Missed opening" reports will
window.
(if auto arm is enabled)
be sent if user disarming has not * or disarmed if
occurred at expiration of
user reenters
"Missed closing" reports
opening window.
premises.
will be sent if user
arming has not
"Late opening" reports will be
occurred at expiration
sent if disarm occurs after
of closing window.
the opening window expires
"Late closing" reports
"Early closing" reports will be
will be sent if system
sent if user arming occurs before
is armed after the
the closing window begins.
closing window
expires.
Programming with #80 Scheduling Menu Mode
The #80 Scheduling Menu Mode is used to programme most of the scheduling
and timed event options.
To enter this mode, the system must first be in normal operating mode (all
partitions disarmed). Enter [Installer Code] + # + 80.
The following can be programmed while in this mode:
• Define time windows
• Assign open/close schedules to each partition
• Assign holiday schedules
• Programme time-driven events (for system functions and relay
activation)
• Assign access control schedules
Some scheduling features are programmed in data field programming mode
(installer code +800). The general programming mode scheduling fields are
listed below.
System Wide Fields:
1*74 -1*75 Relay timeout values
2*01-2*02 Summer time options
2*11
Allow Disarming outside window if
alarm occurs
Partition specific fields: 1*76
Access control relay for this partition
2*05
Auto-arm delay value
2*06
Auto-arm warning time
2*07
Auto-disarm delay value
2*08
Force arm enable
2*09
Open/close reporting by exception
2*10
Restrict disarm only during windows
Event driven relay activation options are programmed using the #93 Menu
Mode, Relay Programming. These actions are in response to a programmed
action. However, relay activation can also be time driven, and thus be used
to initiate a desired action. Time driven relay activation options are
programmed using the #80 Scheduling Menu Mode. Refer to the Time Driven