– 41 –
Wire Size
Maximum
Length
0.64mm
38m
0.81mm
60m
1.0mm
90m
1.3mm
150m
NOTE: DIP switch
position 1 = ON enables
tamper protection. OFF
disables tamper
protection.
SWITCH
4 2 0 4 A D D R E S S S E T T I N G S
POSITION
("—" means "OFF")
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
2
ON
—
ON
—
ON
—
ON
—
ON
—
ON
—
ON
—
ON
—
3
ON
ON
—
—
ON
ON
—
—
ON
ON
—
—
ON
ON
—
—
4
ON
ON
ON
ON
—
—
—
—
ON
ON
ON
ON
—
—
—
—
5
ON
ON
ON
ON
ON
ON
ON
ON
—
—
—
—
—
—
—
—
ON
1
2345
➞
➞
➞
➞
➞
13
14
15
16
C
NC
NO
OFF
➞
ON
➞
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
➞
COVER TAMPER (REED) SWITCH
➞
TB1
4204
TB2
4-PIN KEYPAD PLUG
➞
12
11
10
9
8
7
6
5
4
3
2
1
C
NC
NO
C
NC
NO
C
NC
NO
▲
RELAY
3
RELAY
2
RELAY
1
RELAY
4
TYPICAL
(SHOWN "OFF")
EITHER OR BOTH
CAN BE USED
➞
➞
DATA IN
FROM CONTROL
(–) GROUND
DATA OUT
TO CONTROL
(+) 12V
YEL
BLK
GRN
RED
Figure 15: 4204 Relay Module
Wiring the 4300
Transformer
NOTE: Be sure to
set data field 1*56
50Hz/60Hz to the
appropriate value.
X-10 Powerline Carrier devices are either plugged into standard AC outlets
or wired into the AC electrical system by a licensed electrician, depending on
the type of device used. They respond to "on" and "off" commands sent from
the panel, through the 4300/XF10/XM10E, to the receiving devices. Connect
the 4300 transformer as follows:
1.
Run a 6-conductor cable between the 4300 interface and the panel. Splice
this cable to a 4142TR cable as shown in the diagram below. Note that
the white and yellow wires of the 4142TR must be spliced together.
2.
Set the proper House and Unit Codes for each device following the
instructions provided with each device. Note each device's setup, as these
codes will be used to programme the devices later.
NOTE:
If required, a low-pass filter (available from X-10) can be installed
at the exit of the premises AC network to avoid possible conflict
with nearby powerline carrier systems.
1
2
3
4
5
6
7
8
9
GROUND
GROUND
OUT 6
IN 2
GROUND
IN 3
GROUND
OUT 5
J8 CONNECTOR
BLACK
BLUE
BROWN
GREEN
RED
WHITE
YELLOW
GRAY
VIOLET
4142TR CABLE
1
2
3
4
5
6
TB1
-1
TB1
-30
TB1
-2
AC
Earth
Ground AC
Sync Data Com
4300 TRANSFORMER/INTERFACE
115VAC
60Hz
Figure 16a. 4300 Transformer Connections