5-87
container Commands
Examples
Before removing one or more failover disks from an array, use the
container show failover
command to obtain information
about any existing failover disks assigned to arrays.
As the following example shows, there is an array 0 that has two
failover disks assigned to it on this controller:
AAC0>container show failover
Executing: container show failover
container Scsi C:ID:L
--------- ----------------------------------
0
0:03:0
0:04:0
The following example removes SCSI device 0:03:0 as an assigned
failover disk for array 0:
AAC0>container remove failover 0 (0,3,0)
Executing: container remove failover 0 (CHANNEL=0,ID=3,LUN=0)
Use the
container show failover
command after removing a
failover disk from an array’s failover disk list with the
container
remove failover
command to display information about the
array’s failover disk list, as in the following example:
AAC0>container show failover
Executing: container show failover
container Scsi C:ID:L
--------- ----------------------------------
0
0:04:0
As the display shows, SCSI device (0,03,0) is no longer in the failover
disk list for array 0.
Related Information
container
commands:
■
container set failover
(
page 5-100
)
■
container show failover
(
page 5-112
)
Summary of Contents for 2254100-R - SATA RAID 2410SA SGL/64 Controller
Page 1: ...Adaptec Serial ATA RAID 2410SA Command Line Interface Software Reference Guide R...
Page 52: ...5 13 container Commands disk commands disk remove dead_partitions page 7 9...
Page 78: ...5 39 container Commands disk commands disk show space page 7 22...
Page 194: ...7 10 disk Commands Related Information array commands array list page 5 54...
Page 196: ...7 12 disk Commands Related Information disk commands disk list page 7 5...
Page 232: ...A 2 Automated Scripts...