Acer | HDS WMS100™ User and Reference Guide
249
Appendix C Basic Specifications of the Subsystem
Basic specifications of WMS100 are shown in this chapter.
The basic specifications of floor model and rackmount model are listed and described in
Table C.1 and the basic specifications of the RKNAS are listed and described in Table C.2.
Table C.1
Basic Specifications of WMS100 (continues on the following pages)
Floor Model
Rack-Mount Model
Model
Item
Floor
(RKXS+H1J)
Model
Floor
(RKXS+H2J)
Model
RKXS RKAJAT
Configuration
—
—
1 RKXS
1 RKAJAT
Configuration
Subsystem
appearance
Disk drive size
(W
×
D
×
H) (mm)
101.6
×
146.1
×
25.4
Data capacity
(G byte) (
Note 1
)
245.7/393.4
Rotational speed
(min
-1
)
7,200
Disk drive
used
Maximum mountable
quantity (unit)
15 30
15
Interface type
2 G bps Fibre Channel Optional (Non-OFC) (
Note 3
) —
Data transfer speed
(i.e. maximum speed
for transfer to host)
200 M bytes/s (Fibre Channel) (
Note 4
) —
Single
controller
Fibre Channel: 2 (
Note 2
) —
# of host
connect
ors
Dual
controller
Fibre Channel: 4 (
Note 2
) —
Host Interface
Transferred block size
(bytes)
512 —
Note 1:
The values of storage capacity are calculated as 1 G bytes = 1,000,000,000 bytes.
This definition is different from that (1 k bytes = 1,024 bytes) shown on the PCs you are
using.
Note 2:
When the FC interface board is not added, one port configures one Mini-HUB, and
extends to two host connectors.
When the FC interface board is added, the control unit implements two ports and two host
connectors. One port configures the FC interface independent of another port, and
implements one host connector.
Summary of Contents for HDS WMS100
Page 1: ...MK 95DF738 01 Acer HDS WMS100 User and Reference Guide ...
Page 2: ......
Page 8: ...viii Preface ...
Page 12: ...xii Preface ...
Page 22: ...xxii Contents ...
Page 56: ...34 Chapter 2 Planning for Installation and Operation ...
Page 64: ...42 Chapter 3 Powering On Off Procedure ...
Page 188: ...166 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem Ð ...
Page 192: ...170 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem ...
Page 213: ...Acer HDS WMS100 User and Reference Guide 191 Figure 8 7 NNC Information Screen ...
Page 252: ...230 Chapter 8 Troubleshooting ...
Page 270: ...248 Appendix B System Parameter Settings List ...
Page 316: ...294 Appendix F List of Storage Capacities Corresponding to RAID Levels and Configurations ...
Page 320: ...298 Appendix G Port Address Mapping Table ...