![Acer HDS WMS100 Reference Manual Download Page 131](http://html.mh-extra.com/html/acer/hds-wms100/hds-wms100_reference-manual_8255131.webp)
Acer | HDS WMS100™ User and Reference Guide
109
7.2
Setting Fibre Channel Information
Follow the steps below to set and display fibre channel information:
The Fibre Channel information setting is performed in Management mode of the Storage
Navigator Modular. Therefore, the operation mode of Storage Navigator Modular needs to be
switched from Normal mode to Management Mode. (Refer to section 6.6.) In Normal mode,
you can only monitor the status of WMS100, but you cannot change settings.
Back up all data before performing this procedure. (If a mistake in operation is made, user
data in the subsystem can be lost.)
Note
: Depending on the Fibre Channel interface cable connection pattern, the setting value
needs to be considered. Make the setting to refer to section 4.3.2.
1.
Turn on the power supply.
Note:
If the power supply has already been turned on, proceed to the next step.
2.
Start the Storage Navigator Modular program and set the operation mode in
Management Mode.
3.
Click the icon of an array unit on the Main window and select the Settings menu. Click
Display Details or click Display Details on the toolbar.
4.
On the Tools menu, click Configuration Settings or click the Configuration Settings
button on the toolbar.
5.
Click the Fibre Channel tab.
6.
Set a Port Address, Topology Information, and Transfer Rate:
Port Address: Port address is displayed as a hexadecimal number.
Topology Information: Select Loop or Point-to-Point.
7.
Transfer Rate: Select 1 Gbps, 2 Gbps, 4 Gbps (at the time of adding FC interface board)
or Auto.
8.
Click Apply.
9.
A confirmation message displays. After verifying that the I/O operation initiated by the
host has stopped, click OK.
10.
A message displays stating the setting is completed. Click OK.
Summary of Contents for HDS WMS100
Page 1: ...MK 95DF738 01 Acer HDS WMS100 User and Reference Guide ...
Page 2: ......
Page 8: ...viii Preface ...
Page 12: ...xii Preface ...
Page 22: ...xxii Contents ...
Page 56: ...34 Chapter 2 Planning for Installation and Operation ...
Page 64: ...42 Chapter 3 Powering On Off Procedure ...
Page 188: ...166 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem Ð ...
Page 192: ...170 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem ...
Page 213: ...Acer HDS WMS100 User and Reference Guide 191 Figure 8 7 NNC Information Screen ...
Page 252: ...230 Chapter 8 Troubleshooting ...
Page 270: ...248 Appendix B System Parameter Settings List ...
Page 316: ...294 Appendix F List of Storage Capacities Corresponding to RAID Levels and Configurations ...
Page 320: ...298 Appendix G Port Address Mapping Table ...