Acer | HDS WMS100™ User and Reference Guide
29
2.4.2
Temperature and Humidity Requirements
Table 2.8 lists the temperature and humidity requirements for the WMS100 subsystem.
Table 2.8
Environmental Specifications
Item Specification
In operation (
°
C)
10 to 40
In non-operation (
°
C)
-10 to 50
In transport/storage (
°
C)
-30 to 60
Temperature
Temperature change rate (
°
C/h)
10 or less
In operation (%)
8 to 80
In non-operation (%)
8 to 90
Humidity
Maximum wet bulb temperature (
°
C) 29
(non-condensing)
In operation (m)
-300 to 3,000
Altitude
In non-operation (m)
-300 to 12,000
2.4.3
Input Power and Insulation Performance Specifications
The following tables list the input power and insulation performance specifications for the
WMS100 rack-mount model and the WMS100 floor model.
Conductors shall be provided with 30 A over current protection in accordance with Article
240 of the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part 1,
CSA C22.1, Section 14.
Table 2.9
Input Power and Insulation Performance Specifications for Rack-Mount Model (RKXS)
Rack-Mount Model
Item Model
RKXS RKAJAT
Input voltage (V)
AC 100/200 (100-120/200-240)
Frequency (Hz)
50/60
±
1
Number of phases, cabling
Single-phase with protective grounding
Steady-state current (A) (
Note1
) (
Note2
) 3.0
×
2/1.5
×
2 2.4
×
2/1.2
×
2
Breaking current (A)
16.0
Steady state (VA)
600 or less
480 or less
Required power
Starting state (VA)
600 or less
480 or less
Input power
specification
Heat value (kJ/h)
2,160 or less
1,730 or less
Insulation
Insulation withstand voltage
AC 1,500 V (10 mA, 1 min)
performance
Insulation resistance
DC 500 V, 10 M
Ω
or more
Note 1:
Power current of Nx2 described above is required for operation by a single power supply unit.
Note 2:
It indicates the current consumption in the usual state. When a power supply failure occurs, the power
consumption is provided by the single power supply for the subsystem.
Summary of Contents for HDS WMS100
Page 1: ...MK 95DF738 01 Acer HDS WMS100 User and Reference Guide ...
Page 2: ......
Page 8: ...viii Preface ...
Page 12: ...xii Preface ...
Page 22: ...xxii Contents ...
Page 56: ...34 Chapter 2 Planning for Installation and Operation ...
Page 64: ...42 Chapter 3 Powering On Off Procedure ...
Page 188: ...166 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem Ð ...
Page 192: ...170 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem ...
Page 213: ...Acer HDS WMS100 User and Reference Guide 191 Figure 8 7 NNC Information Screen ...
Page 252: ...230 Chapter 8 Troubleshooting ...
Page 270: ...248 Appendix B System Parameter Settings List ...
Page 316: ...294 Appendix F List of Storage Capacities Corresponding to RAID Levels and Configurations ...
Page 320: ...298 Appendix G Port Address Mapping Table ...