208
Chapter 8 Troubleshooting
8.4.5.2
Flash Detected Messages
When the following Flash detected messages are displayed, follow the instructions to resolve
the problem.
Table 8.7
Flash Detected Messages
Message Code
Message Text
Recovery Measures
RA00xx
Microprogram error [FLS]
RA7000
Microprogram revision mismatch
Restarting the equipment.
RB0000
Upload system error
Check the microprogram you want to install and install it over
again.
RB0600
No micro program
Perform the new installation upgrade.
RB0A00
Upload file SUM check error
A sum check error occurred in a read file during an upload.
Check the microprogram you want to install and install it over
again.
RB0E00
Up grade check NG
The upgrade check of the microprogram failed. (An upgrade
version of a microprogram does not conform to the
microprogram being upgraded.) Do a new install of the
microprogram.
RB3000 File
size
error
RB3100
File open error
RB3200
File read error
RB3500
Bad block ID
RB3600
Bad LBA in START 600 DAT
RB7000
Program size too large
Check the microprogram you wish to install.
RB8000
Old microprogram exists
If the installation can be continued, the RAID group and LU
deformation are initialized. (In this case, all the data in the disk
drive are deleted. When the data in the disk drive need to be
saved, stop the work and perform the update installation.
RB8300
Empty system retry full install
The update installation cannot be executed because a system
does not exist in the disk drive.
Execute a new installation.
RBA000
Down grade check NG
The present microprogram version cannot be updated to a
specified microprogram version.
Check the work procedure.
Execute a new installation.
When a Flash detected message other than those shown above is displayed, inform your
Customer Engineer of the message code.
Summary of Contents for HDS WMS100
Page 1: ...MK 95DF738 01 Acer HDS WMS100 User and Reference Guide ...
Page 2: ......
Page 8: ...viii Preface ...
Page 12: ...xii Preface ...
Page 22: ...xxii Contents ...
Page 56: ...34 Chapter 2 Planning for Installation and Operation ...
Page 64: ...42 Chapter 3 Powering On Off Procedure ...
Page 188: ...166 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem Ð ...
Page 192: ...170 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem ...
Page 213: ...Acer HDS WMS100 User and Reference Guide 191 Figure 8 7 NNC Information Screen ...
Page 252: ...230 Chapter 8 Troubleshooting ...
Page 270: ...248 Appendix B System Parameter Settings List ...
Page 316: ...294 Appendix F List of Storage Capacities Corresponding to RAID Levels and Configurations ...
Page 320: ...298 Appendix G Port Address Mapping Table ...