Acer | HDS WMS100™ User and Reference Guide
213
8.4.6
Reading Failure Information
The history of the unit, after it is turned on, is displayed in the Information Message.
The Subsystem is Ready message displays the time when the unit is ready. Messages
sent after the power is turned on until the unit is ready are displayed prior to this
message. Messages sent after the unit is ready are displayed after this message.
Carefully observe the following: Wxxxxx (Warning message), Hxxxxx (Failure message),
and Rxxxxx (Flash detection message).
The following messages are displayed when failures occur and when they are solved. If
the recovery message is displayed after a failure occurrence message, the failure has
been solved.
Table 8.11 How to Read Failure Information
No.
Description
Failure Detection Messages
Failure Recovery Messages
1 Controller
error/
recover
W0100x
: CTL alarm (CTL-x)
I0010x
: CTL recovered (CTL-x)
2 error/recovery
W0D0x0
: Cache alarm (CTL-y, CACHE-z)
I0020z
: Cache recovered (CACHE-z)
W03000
: Battery alarm
W03100
: Battery removed
W03200
: Battery SW OFF
3 Cache
memory
error/recovery
W03300
: Battery thermal alarm
I00300
: Battery recovered
4
Battery backup board
error/recovery
W0340x
: Battery backup circuit alarm
(CTL-x)
I0040x
: Battery backup circuit recovered
(CTL-x)
5 Fan
error/recovery
W04000
: FAN alarm (Unit-x, FAN-y)
I00500
: FAN recovered (Unit-x, FAN-y)
6
Power supply error/
recovery
W050xy
: PS alarm (Unit-x, PS-y)
I006xy
: PS recovered (Unit-x, PS-y)
7
Disk drive error/ recovery
W060xy
: HDU alarm (Unit-x, HDU-y)
I007xy
: HDU recovered (Unit-x, HDU-y)
8
Spare disk error/ recovery
W061xy
: Spare HDU alarm
(Unit-x, HDU-y)
I009xy
: Spare HDU recovered
(Unit-x, HDU-y)
9 Loop
error/recovery
W080xy
: Loop alarm (Path-x, Loop-y)
I00Axy
: Loop recovered
(Path-x, Loop-y)
10 UPS
error/recovery
W0C000
: UPS alarm (UPS-x)
I00D00
: UPS recovered (UPS-x)
11 NCC
partial
error/recovery
W5010x
: NNC partial alarm
(NNC-x)
IA100x
: NNC recovered from partial alarm
(NNC-x)
12 NCC
error/recovery
W5000x
: NNC alarm (NNC-x)
IA1V0x
: NNC recovered (NNC-x)
Summary of Contents for HDS WMS100
Page 1: ...MK 95DF738 01 Acer HDS WMS100 User and Reference Guide ...
Page 2: ......
Page 8: ...viii Preface ...
Page 12: ...xii Preface ...
Page 22: ...xxii Contents ...
Page 56: ...34 Chapter 2 Planning for Installation and Operation ...
Page 64: ...42 Chapter 3 Powering On Off Procedure ...
Page 188: ...166 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem Ð ...
Page 192: ...170 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem ...
Page 213: ...Acer HDS WMS100 User and Reference Guide 191 Figure 8 7 NNC Information Screen ...
Page 252: ...230 Chapter 8 Troubleshooting ...
Page 270: ...248 Appendix B System Parameter Settings List ...
Page 316: ...294 Appendix F List of Storage Capacities Corresponding to RAID Levels and Configurations ...
Page 320: ...298 Appendix G Port Address Mapping Table ...