Explanation of “RS422” parameters in Mira Engineering Setup menu.
Mira 4-Channel & 8-Channel Servers
To open the Mira
Engineering Setup
window shown below,
perform the procedure “
Launching Mira Engineering Setup Utility
Protocol
This set of radio buttons assigns the RS422 serial protocol to the currently selected
Room Configuration
(pull-down located above the radio buttons
).
BVW-75
Assigns Sony BVW-75 protocol to the selected Room; no Clip ID listing & loading.
Odetics
Assigns Odetics protocol to the selected Room; supports Clip ID listing & loading.
VDCP (Louth Protocol)
Assigns VDCP protocol to the selected Room; supports Clip ID listing & loading.
AMP over Ethernet
Assigns AMP protocol to the selected Room; supports Clip ID listing & loading.
Protocol Configuration
This area will change according to the currently selected Protocol.
Disable field timecode reporting
This parameter determines how often timecode is reported on the RS422 serial control
port. Some external controllers expect to see timecode once every field of video; while
others expect to see timecode once every frame of video.
Unchecked = timecode reported every field of video.
Checked = timecode reported every frame of video.
Protocol ID
This parameter determines which “Device ID” is sent down the RS422 serial control
port to the controlling device when queried by the controller.
Louth Preview
In VDCP protocol, this command allows clip ID’s to be “pre-cued” in the background,
providing seamless transitions when playing back-to-back clips. If this command is
turned OFF in Mira, there may be frozen video at the end of clips when played back-
to-back.
Unchecked = Preview support turned OFF.
Checked = Preview support turned ON.
Response Time
Fast = best for applications where an operator initiates each action.
Accurate = best for automation systems.