User Operations Guide—Mira Instant Replay Server
196
Copyright ©2014, Abekas Incorporated
Revised: 5 September 2014
Instant Replay with Stereoscopic 3D Cameras for Mira 4-Channel Server
Use this procedure to configure Mira for Stereoscopic 3D (3D) paired channels that will be used for instant replay applications. The RS422
serial control port is required only on the “LEFT” channel.
Each 3D channel pair can be used as either a recorder or player (
a given 3D channel
cannot record and play at the same time
).
IMPORTANT NOTE:
If you wish to use Mira for stand-alone 3D operation, then please use the procedure “
” on page 179 above.
Mira 4-Channel Server
To open the Mira
Engineering Setup
window shown below,
perform the procedure “
Launching Mira Engineering Setup Utility
1.
Click “
Channels
” tab.
2.
Click radio button for “
VV VV
” channel-pairing.
3.
Click
to accept changes.
Group for Channels A through D
VV VV
(
ChA
=3D LEFT #1) + (
ChC
=3D RIGHT #1)
.
(
ChB
=3D LEFT P1) + (
ChD
=3D RIGHT P1)
.
RS422=
ChB
.
to (DMAT-AB RS422 port #1)
DMAT-AB control panel operates in “1R/1P” mode in MENU.