label, located either on the lower arm, underneath the flange plate on the base or
on the frame.
At delivery the manipulator is in the correct position, do NOT rotate axis 4 or 6 at
power up before the revolution counters are updated.
If one of the following mentioned axes are rotated one or more turns from its
calibration position before updating the revolution counter, the correct calibration
position will be lost due to non-integer gear ratio. This affects the following
manipulators:
Axis 6
Axis 4
Manipulator variant
No
No
IRB 2400
If the synchronization marks seem to be wrong (even if the motor calibration data
is correct), try to rotate the axis one turn, update the revolution counter and check
the synchronization marks again (try both directions, if needed).
Step 2 - Updating the revolution counter with the TPU
Use this procedure to update the revolution counter with the TPU (BaseWare 4.0).
Note
Action
Press the button
Miscellaneous
then
ENTER
to select the service
window.
xx0100000194
1
Select
Calibration
from the
View
menu.
The
Calibration window
appears.
If there is more than one unit connected to the manipulator, they will
be listed in the window.
xx0100000201
2
Continues on next page
Product manual - IRB 2400
211
3HAC022031-001 Revision: P
© Copyright 2004-2018 ABB. All rights reserved.
5 Calibration information
5.5 Updating revolution counters
Continued
Summary of Contents for IRB 2400 Series
Page 1: ...ROBOTICS Product manual IRB 2400 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 204: ...This page is intentionally left blank ...
Page 220: ...This page is intentionally left blank ...
Page 232: ...This page is intentionally left blank ...
Page 234: ...This page is intentionally left blank ...
Page 240: ......
Page 241: ......