Removal, drive shaft unit
The procedure below details how to remove the drive shaft unit from the robot
upper arm.
NOTE! ABB recommends its customers to carry out only the following servicing
and repair work on the drive shaft unit
.
Note/Illustration
Action
DANGER
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
1
Detailed in section
Remove the wrist.
2
Detailed in section
tors, axes 4-6, IRB 2400L on page 183
.
Loosen the connection box and disconnect
the connectors on the motors of axes 5 and
6. Mark the motor number on the motors, to
simplify the reconnecting.
3
xx0300000021
Undo the screws.
4
•
A: Screws
•
B: Motor screws
Squeeze the drive shafts together at the tip
of the tubular shaft, so they can pass
through the tube.
5
Pull out the complete drive mechanism of
axes 5 and 6.
6
Detailed in section
tors, axes 4-6, IRB 2400L on page 183
.
Undo the screws and nuts, holding the mo-
tors and remove both motors.
7
Undo the screws and remove the motor
plate.
8
Remove the gear belts.
9
Continues on next page
Product manual - IRB 2400
201
3HAC022031-001 Revision: P
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.8.2 Replacement of drive shaft unit, IRB 2400L
Continued
Summary of Contents for IRB 2400 Series
Page 1: ...ROBOTICS Product manual IRB 2400 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 204: ...This page is intentionally left blank ...
Page 220: ...This page is intentionally left blank ...
Page 232: ...This page is intentionally left blank ...
Page 234: ...This page is intentionally left blank ...
Page 240: ......
Page 241: ......