Note/Illustration
Action
xx0200000399
Remove the rear cover plate (A) on the ro-
bot by unscrewing its attachment screws
(B).
3
Disconnect connectors R1.MP4-6 and
R2.BU4-6.
4
xx0200000403
Disconnect all the earth cables on the
R1.M4-6 cable from the back of the cover.
5
Loosen the nuts holding the SMB-unit
slightly, then remove it carefully from the
bracket.
6
The cable between the battery and the
SMB-unit may stay connected, in order to
avoid recalibration of the robot. Be careful
not to let the weight of the SMB-unit strain
the cable!
In order to remove the SMB-unit com-
pletely, the connector R2.G must be discon-
nected! This causes a necessary recalibra-
tion of the robot!
Disconnect connector R2.FB 4-6 from the
connection R2.SMB4-6 on the SMB-unit.
7
This releases the cable harness from the
frame.
Unscrew the four screws securing the cable
gland.
8
xx0200000404
Remove the adapter plate from the harness
by removing its two attachment screws (A).
9
Note! Different robot versions are fitted
with different plate versions. Make sure
the correct one is used to avoid cable
failure.
Continues on next page
128
Product manual - IRB 2400
3HAC022031-001 Revision: P
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.3.2 Replacement of cable harness, axes 4-6
Continued
Summary of Contents for IRB 2400 Series
Page 1: ...ROBOTICS Product manual IRB 2400 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 204: ...This page is intentionally left blank ...
Page 220: ...This page is intentionally left blank ...
Page 232: ...This page is intentionally left blank ...
Page 234: ...This page is intentionally left blank ...
Page 240: ......
Page 241: ......