Refitting, wrist unit
The procedure below details how to refit the wrist unit to the robot.
Note
Action
DANGER
Turn off all electric power, hydraulic and pneumatic
pressure supplies to the robot!
1
Clean the surface of the tubular shaft.
2
Apply Loctite 574 all around.
3
Tightening torque: 8.3 Nm +10%.
Fit the wrist, tighten the attachment screws.
4
Screw the clamping sleeves together using screws
to a torque of 5.7 Nm.
5
Refit the plugs.
6
Refit the cover at the motor side of axis 5-6.
7
Calibration is detailed in a separate
calibration manual enclosed with
the calibration tools.
Calibrate the robot!